Minutes of the
59th MTE meeting held on Thursday July 5th 2012
|
Present :
R. Brown,
S. Damjanovic, R. Fernandez Ortega, M. Giovannozzi, M. Hourican, S.
Gilardoni
|
Excused :
J. Borburgh, C. Hernalsteens, J.-M. Lacroix, S.
Mataguez, S. Roesler,
|
Main items
Conclusions and actions from
the meeting |
List of action to be co-ordinated by TE-ABT:
-
Check the need of additional vacuum
pumping and whether there could be issues with
outgassing in particular for future ions runs.
-
Check the proposed layout of the
shield with transport, including also the availability
of concrete blocks at CERN and the total charge of the
shielding. The layout should be
optimised in order to minimise the dose delivered
to personnel during intervention (i.e., easy dismantling
of the blocks). In particular, it should be checked
whether non-standard dimensions could be useful to
provide easy access for the downstream part of the
shielding.
-
The emergency system to move the
dummy septum blade should be controlled by one single
crank.
-
Scenarios concerning possible
interventions on the dummy septum should be defined.
these will then be used to estimate the dose delivered
to personnel.
-
It should be checked what is the
status of MMU14 and MMU15 in terms of recent
refurbishment.
-
the final layout of the dummy septum
should be circulated for impedance estimate. It seems
from preliminary computation that trapped modes might
require ferrites to be installed. If confirmed, impact
on vacuum should be checked.
|
|
|