Minutes of the
87th MTE meeting held on Thursday March 20th 2014
|
Present :
S. Burger, M. Giovannozzi, N. Jurado, P. Van Trappen.
|
Excused :
S. Gilardoni, M. Hourican.
|
Main items
Conclusions and actions from
the meeting |
-
Status of MTV:
-
Overall tests in local configuration where
successfully performed.
-
The marguerite is working fine, even if the
filters will be installed later on.
-
Next tests or actions to be performed
(Action: Stephane)
-
The video signal transmission should be
checked.
-
The panel with the equipment for the
pneumatic system is installed on the inner side of the
shielding: it should be checked whether there is a possible
conflict with the removal of the main bus bars cover.
-
A general test controlling the device
from the CCC should be performed.
-
The camera should be re-oriented with the
dummy septum blade in its nominal position, i.e. 87 mm from
the circulating beam.
-
TPS15 blade movement tests:
-
The movement system has been successfully
tested and commissioned.
-
The target accuracy of 100
mm has been almost achieved
after having performed a number of detailed tests and
improvements.
-
Next tests or action to be performed (Action:
Mike, Pieter)
-
The blade position should
correspond to the position of the inner surface of the
blade, i.e., the one facing the circulating beam.
-
The upstream blade position should
be given at the upstream extremity of the blade and not at
the position of the motor moving the blade. The same applies
to the downstream blade position.
-
In the CCC we should control the
upstream (as defined above) blade position and the blade
angle. The downstream blade position should a read only
parameter that can be used to check the consistency of the
upstream position and angle.
|
|
|